SPECIFICATIONS
200% of rated voltage applied through a minimum limiting resistance of 100 Ohms/Volt. Duration of voltage stress shall be 15 seconds minimum and 1 minute maximum at 25°C.
At 25°C after 2 minutes of electrification at rated voltage or 500 VDC, whichever is less, the minimum product of Insulation Resistance and Capacitance shall be 100,000 megohms-microfarads, but need not exceed 100,000 megohms.
Shall not exceed 0.1% when measured at 25°C and 1000 Hz, ±20 Hz. See characteristic curves for D.F. ratings at other temperatures.
See ratings and dimensions, next page. RATED CURRENT See ratings and dimensions, next page. CAPACITANCE AND TOLERANCE Shall be measured within the tolerance limits specified. Measurements will be made at 25°C and 1000 Hz, ±20 Hz.
Shall withstand 140% of rated voltage at 105°C for 250 hours. One failure in twelve shall be permitted.
Capacitance shall change linearly over operating temperature range range of -55°C to +85°C at rate of -290, ±75 parts per million/°C.
Less than .2% when measured in the following manner: three capacitance readings at 25°C, each made prior to and after temperature cycling from room to 105°C, and room to -55°C. The mathematical difference between the two extremes, divided by the intermediate value, and then multiplied by 100, yields the stability expressed in percent. |
GENERAL DATA All of the above style capacitors are intended specifically
for use in switching power supplies. They are enclosed in a flame
retardant housing that meets IEC publication 695-2-2, Needle
Flame Test, Condition B. UL510 is also satisfied with this enclosure.
FEATURES
APPLICATIONS
HUMIDITY RESISTANCE Meets requirements of Mil-C-27287, Para. 3.12 when tested
in accordance with Mil-STD.-202, Method 103 B, Condition B. LEAD PULL AND BEND TEST Steady pull of 5 pounds applied axially to leads for one minute.
Bend test shall consist of one bend from the point of egress,
first 90° in one direction, back to the original axial position,
and then 90° in the opposite direction with no evidence of
breakage. TEMPERATURE RANGE -55°C to +105°C with full rated voltage applied. DIELECTRIC ABSORPTION Shall not exceed .05% when tested in accordance with Mil-C-19978. |